MULTIFIX Filter regulator, G 1/4", 0,1 to 3bar, model series 0

Item number:

FR 014-3 AM

€108.89
pcs
Item description
Version:
Self-relieving pressure regulator with additional filtering using the centrifugal principle and sintered filter

Materials:
Body: die-cast zinc Z410 (model series 4 & 5: aluminium), spring hood: POM, diaphragms and seals: NBR, condensate container: polycarbonate

Temperature range:
-10 to +60 °C

Input pressure:
1.5 - 16 bar (model series 0 when using coupling kit 1.5 - 12 bar)

Pressure gauge connection:
G 1/4" (model series 0: G 1/8")

Pore width in the filter:
5 µm (model series 5: 40 µm)

Condensate draining:
semi-automatic****

Media:
Compressed air, neutral gases

Advantages:
•Automatic venting in the event of overpressure on the secondary side,
•Easy assembly of individual components using coupling kits within a model series and thread size,
•Hand wheel can be locked by pressing down on it


Max. condensate amount:
16 cm³

Switch panel thread:
M 30x1,5

Scope of delivery:
Pressure regulator including 40 mm pressure gauge

Flow:
1450 l/min ***

ATEX:
Operating material without its own potential source of ignition in accordance with Directive 2014/34/EU (not E-11 closure)

Optional:
can be locked using a cylinder lock -K, can be locked using a cylinder lock with E 11 closure** -KE11, version with metal bowl and without inspection tube -MB, automatic discharge -AM, automatic discharge closed when not pressurised (0 - 16 bar) -AMNC
Properties
Ver­sion Fil­ter reg­u­la­tor
Thread G 1/4"
Pres­sure reg­u­la­tion range [bar] 0,1 - 3
Con­tainer de­sign Plas­tic con­tainer
Con­den­sate drain au­to­matic
Pres­sure gauge dis­play [bar] 0 - 4
Mount­ing brack­ets W 0
Mount­ing brack­ets with panel union nut MW 1
Cou­pling kit KP 0
input pres­sure [bar] 1,5 - 16
Further information on FR014-3AM
Weight 390 g / pcs
Customs duty number 84811005
RoHS compliant Yes
Documents
*Standard series, please prefer for use, since the pressure regulation range is universally usable, **Volkswagen closer (is supplied without a spanner), ***measured at P1 = 10 bar, P2 = 6.3 bar and 1 bar pressure drop, ****As soon as the input pressure drops below the minimum input pressure, the drain valve opens automatically. By screwing the drain screw tight, the semi-automatic opening of the drain valve can be prevented.

 
All data are to be understood as non-binding reference values! We do not assume liability for any data selection not confirmed in writing. Unless otherwise specified, pressure values refer to liquids from Group II at +20°C.
Immediately available